AC Mini Clamp Meter MS2107
Key Specifications / Features
Model No.: MS2107 Hits: 1
♦Jaw opening:Φ12.5mm
♦Auto range/Manual range
♦Display:4000 count LCD display (3 3/4 digit)
♦Overload protection:use the PTC protection circuit for resistance diode and continuity
♦DATA HOLD function
♦Back light function
♦AC Voltage detection function(NCV)
♦Low battery indication
♦Auto power off
♦Operating temperature&Humidy:0~40℃(32~104℉)&<80%RH
♦Storage temperature&Humidy:-10~50℃(14~122℉)&<70%RH
♦Power supply:1.5V battery x 3
♦Safety class:IEC61010-1,CATIII 600V
♦Dimension:21.3mmx55mmx29mm
♦Weight:approx. 310g
Request a quote
Share
♦Auto range/Manual range
♦Display:4000 count LCD display (3 3/4 digit)
♦Overload protection:use the PTC protection circuit for resistance diode and continuity
♦DATA HOLD function
♦Back light function
♦AC Voltage detection function(NCV)
♦Low battery indication
♦Auto power off
♦Operating temperature&Humidy:0~40℃(32~104℉)&<80%RH
♦Storage temperature&Humidy:-10~50℃(14~122℉)&<70%RH
♦Power supply:1.5V battery x 3
♦Safety class:IEC61010-1,CATIII 600V
♦Dimension:21.3mmx55mmx29mm
♦Weight:approx. 310g
Tags:
Next: Digital Clamp Meter MS2001
Previous: AC Digital Clamp Meter MS2108A
Detail Infomation
Electrical Specification | |||
Function | Range | Best. Resolution | Accuracy |
AC Current | 4A/40A | 1mA | ±(1.5%rdg+3rdg) |
DC Current | 4A/40A | 1mA | ±(1.5%rdg+3rdg) |
AC Voltage | 400mV/4V/40V/400V/600V | 0.1mV | ±(1.0%rdg+3rdg) |
DC Voltage | 400mV/4V/40V/400V/600V | 0.1mV | ±(0.8%rdg+3rdg) |
Resistance | 400Ω/4KΩ/40KΩ/400KΩ/4MΩ | 0.1Ω | ±(0.8%rdg+3rdg) |
40MΩ | 0.01MΩ | ±(1.2%rdg+3rdg) | |
Continuity Check | Buzzer sounds at less than 30Ω(open circuit voltage:about 2.8V) | ||
DIode Check | Testing current:about 1.5mA(open circuit voltage:about 2.8V) |